Pressure sensor with display PN3094 PN-010-RER14-MFRKG/US/ /V
Pressure sensor with display PN3094
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1
Measuring range
-1...10 bar -14.5...145 psi -0.1...1 MPa
Process connection threaded connection G 1/4 Internal thread M6 I
Application
System gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Media liquids and gases
Medium temperature[°C] -25...80
Min. bursting pressure
150 bar 2175 psi 15 MPa
Pressure rating
75 bar 1087 psi 7.5 MPa
Vacuum resistance
-1000 mbar -0.1 MPa
Type of pressure relative pressure; vacuum
Electrical data
Operating voltage[V] 18...30 DC; (to SELV/PELV)
Current consumption[mA] < 35
Min. insulation resistance[MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time[s] < 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; IO-Link; (configurable)
Electrical design PNP
Number of digital outputs 1
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC[V] 2.5
Permanent current rating of switching output DC[mA] 150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC[Hz] < 170
Number of analog outputs 1
Analog current output[mA] 4...20; (0 bar = 4 mA; 10 bar = 20 mA)
Max. load[Ω] 500
Analog voltage output[V] 0...10; (0 bar = 0 V; 10 bar = 10 V)
Min. load resistance[Ω] 2000
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range
-1...10 bar -14.5...145 psi -0.1...1 MPa
Factory setting / CMPT = 2
Set point SP
-0.9...10 bar -13.5...145 psi -0.09...1 MPa
Reset point rP
-0.95...9.95 bar -14...144.5 psi -0.095...0.995 MPa
Min. difference between SP and rP
0.05 bar 1 psi 0.005 MPa
In steps of
0.05 bar 0.5 psi 0.005 MPa
Status_B High Resolution / CMPT = 3
Set point SP
-0.92...10 bar -13.3...145 psi -0.092...1 MPa
Reset point rP
-0.97...9.95 bar -14...144.3 psi -0.097...0.995 MPa
Min. difference between SP and rP
0.05 bar 0.8 psi 0.005 MPa
In steps of
0.01 bar 0.1 psi 0.001 MPa
Accuracy / deviations
Switch point accuracy[% of the span] < ± 0,5
Repeatability[% of the span] < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span] < ± 0,25
Long-term stability[% of the span] < ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] < ± 0,2; (-25...80 °C)
Temperature coefficient span[% of the span / 10 K] < ± 0,2; (-25...80 °C)
Reaction times
Response time[ms] < 3
Delay time programmable dS, dr[s] 0...50
Damping process value dAP[s] 0...4
Damping for the analog output dAA[s] 0...4
Max. response time analog output[ms] 3
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port class A
Process data analog 1
Process data binary 1
Supported DeviceIDs
Type of operation DeviceID
Factory setting / CMPT = 2 431
Status_B High Resolution / CMPT = 3 615
Note
For further information please see the IODD PDF file at "Downloads"
Factory setting / CMPT = 2
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time[ms] 2.3
IO-Link resolution pressure
0.01 bar 0.001 MPa
IO-Link process data (cyclical)
Function bit length
pressure 14
binary switching information 1
IO-Link functions (acyclical) application specific tag
Status_B High Resolution / CMPT = 3
Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time[ms] 3
IO-Link resolution pressure
0.005 bar 0.0005 MPa
IO-Link process data (cyclical)
Function bit length
pressure 16
device status 4
binary switching information 1
IO-Link functions (acyclical) application specific tag
Operating conditions
Ambient temperature[°C] -25...80
Storage temperature[°C] -40...100
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF[years] 226
UL approval
UL approval number J004
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight[g] 235.5
Housing tubular
Dimensions[mm] Ø 34 / L = 90.7
Material stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts) stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM
Min. pressure cycles 100 million
Tightening torque[Nm] 25...35; (recommended tightening torque; Depends on lubrication, seal and pressure rating)
Process connection threaded connection G 1/4 Internal thread M6 I
Restrictor element integrated no (can be retrofitted)
Displays / operating elements
Display of IFM PN3094 Pressure Sensor with Display PN-010-RER14-MFRKG/US/ /V Sensor In Stock
Display unit 3 x LED, green (bar, psi, MPa)
Switching status 1 x LED, yellow
Measured values alphanumeric display, red/green 4-digit
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated
More Models:
EVC810 IIR200 PK5524 EVC005 II0011 EVC004 SI5002 IGT205 O1D100 PQ3834 IFS204 TA2105 IFM216 EVF566 II5930 II5697 EVC002 IG5596 SI5010 II5687 KF5015 VTV122 SA5000 E21248 PN3094 SI6700 E30448 OY039S EY3099 E11855 G1501S E11252 PM1608 AL1930 EVC146 EVT006 LI5131 PT5404 PN7299 PN7209 AC1254 AC1258 SI6800 EC2082 AL1102 UGT524 EVC086 EVC003 OGH500 II5689 AC5222 AC5218 AC5233 SU7000 PN3093 PN2160 IM5115 SH0500 LR2050 MVQ101 IFC248 IFC234 IFC220 IN5225 IFT203 O5E700 IG6086 E12339 IGC222 EVC714 IGW201 IF5888 EVC597 IM5126 IGT220 IG5505 IG5401 EVS023 EVC812 VTV121 IIS204 IM0011 SM9000 IGT213 IFT205 PN2093 PN2094 E20005 OGE101 OGS100 PM1506 E33403
We mainly supply Siemens, Schneider, Honeywell, ABB, Allen Bradley, Mitsubishi, Omron, Eaton, Pepperl+Fuchs, MTL, Phoenix Contact,Weidmuller, Festo, IFM, Wago, Pilz, Degson, Sick, SMC, Norgren, Yokogawa, Yaskawa, Fluke, SEW, Emerson,Endress+Hauser,Vega, Hirschmann,Moxa, CISCO, Turck, Beckhoff, B&R, Balluff, Bifold, GE,Rittal, Proface, Wintek,Danfoss,EBM, YTC,Hach,Delta, Finder,Wohner, CHINT, Autonics,Testo, Bently Nevada, PR Electronics, Meanwell, Dell and so on .
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
Contact: